MAN 650066:D
1
VACUUM FLUORESCENT DIGITAL DASHBOARD
SERIES 3
NOW WITH
SOLID STATE SENSOR TECHNOLOGY
INSTALLATION AND OPERATION MANUAL
Please read this before beginning installation or wiring.
IMPORTANT NOTE!
This
system
available for the first 100 miles (160km) of operation. See odometer preset section
for instructions
and setup information
.
Vista de pagina 0
1 2 3 4 5 6 ... 31 32

Indice de contenidos

Pagina 1 - SERIES 3

MAN 650066:D 1 VACUUM FLUORESCENT DIGITAL DASHBOARD SERIES 3 NOW WITH SOLID STATE SENSOR TECHNOLOGY INSTALLATION AND

Pagina 2 - Message Center

MAN 650066:D 10 SPD + This terminal is used to supply power to Dakota Digital speed sensor SEN-01-5. This supplies 5V DC to the sen

Pagina 3 - WARNING

MAN 650066:D 11 systems with one message display the speed/performance and rpm/warn messages will use the same display. To enter DEM

Pagina 4

MAN 650066:D 12 WTR – This is the ground reference used for two-wire water temp sensors. This will connect to one of the wires from

Pagina 5

MAN 650066:D 13 FUEL SND The fuel gauge sending unit is not normally supplied because the display system can use the existing fuel s

Pagina 6

MAN 650066:D 14 GEAR (1 wire) The GEAR terminal is used for the gear shift indicator. The indicator is built into every system, but

Pagina 7 - CONTROL BOX MOUNTING

MAN 650066:D 15 CHECK ENG (-) The check engine terminal is used with fuel injection ECM’s to display engine problems and trouble cod

Pagina 8 - (2k or 4k PPM)

MAN 650066:D 16 Setting up the control box Below is a list of all of the setup menus. You must have SW1 wired to enter setup; des

Pagina 9

MAN 650066:D 17 SPEEDOMETER SETUP/CALIBRATION There are two main methods for calibrating the speedometer, auto cal and adjust. Auto

Pagina 10

MAN 650066:D 18 (Auto Cal continued) NOTES: You do not have to drive at a constant speed nor do you have to avoid stopping during Au

Pagina 11

MAN 650066:D 19 Speed Output (OUTPUTOUTPUTOUTPUTOUTPUT) If a speed signal is needed for an ECM or cruise control, the SPD OUT termin

Pagina 12

MAN 650066:D 2 Thank you for purchasing the Vacuum Fluorescent Digital Dashboard from DAKOTA DIGITAL, the leader in custom automot

Pagina 13

MAN 650066:D 20 Display update setup (UPDATEUPDATEUPDATEUPDATE) The display update rate can be adjusted so the reading on the tach

Pagina 14

MAN 650066:D 21 WATER TEMP SETUP The water temp setup allows you select the units the temperature is displayed in, Fahrenheit or Cel

Pagina 15

MAN 650066:D 22 Temp sensor test (testtesttesttest) This menu will allow you to check the resistance the control box is reading fr

Pagina 16 - Setting up the control box

MAN 650066:D 23 Oil pressure sensor test (testtesttesttest) This menu will allow you to check the voltage the control box is readi

Pagina 17

MAN 650066:D 24 Fuel sensor setup (SENDERSENDERSENDERSENDER) This menu is used to select the fuel level sensor type. The table ab

Pagina 18

MAN 650066:D 25 Exit fuel setup (donedonedonedone) This will allow you to exit the fuel setup and go on to the next setup menu. •

Pagina 19 - TACHOMETER SETUP

MAN 650066:D 26 BUS INTERFACE MODULE SETUP The bus interface modules (BIM) are a future product added to Dakota Digital instrumentat

Pagina 20 - VOLT SETUP

MAN 650066:D 27 TROUBLESHOOTING GUIDE This is a list of some problems and their solutions which may be encountered when installi

Pagina 21 - WATER TEMP SETUP

MAN 650066:D 28 Symptom Possible Problem Solution ------------------------------------------------------------------------

Pagina 22 - OIL PRESSURE SETUP

MAN 650066:D 29 Symptom Possible Problem Solution ------------------------------------------------------------------------

Pagina 23 - FUEL SETUP

MAN 650066:D 3 WARNING The vacuum fluorescent displays are made of glass and should be handled with care. MOUNTING UNIVERSAL DISP

Pagina 24

MAN 650066:D 30 Symptom Possible Problem Solution ------------------------------------------------------------------------

Pagina 25 - NIGHTTIME DIM SETUP

MAN 650066:D 31 Setting the time Through lens: Using a small, thin object such as a pen or hairpin, press “set” buttons through fr

Pagina 26 - ODOMETER PRESET MENU

MAN 650066:D 32 VFD3 Specifications SUPPLY Voltage Input (+12) Range 8 to 22 V INPUTS Active High Low Max Min High High, Left, Ri

Pagina 27 - TROUBLESHOOTING GUIDE

MAN 650066:D 4 MOUNTING KITS INTO ORIGINAL DASHES Some kits will include a separate mounting instruction sheet so please see that

Pagina 28

MAN 650066:D 5 GAUGE SYSTEM FEATURES Mileage readings • Million mile odometer • Two (A/B) re-settable trip mileage (0-9999.9) • R

Pagina 29

MAN 650066:D 6 MESSAGE DISPLAYS On systems with two message displays, Switch 1(SW1) will toggle between the speed message displays

Pagina 30 - Clock Instructions

MAN 650066:D 7 CONTROL BOX MOUNTING Once the display panel is in place, mount the control box within reach of the ribbon cable on t

Pagina 31

MAN 650066:D 8 TACH POWER GROUND WARN DIM (+) SPD + SPD SND SPD - SPD OUT SW2 (-) SW1 (-) ADJ SND ADJ - WTR SND WTR - OIL + OIL SND

Pagina 32

MAN 650066:D 9 POWER Connect the POWER terminal to accessory +12V power from the fuse panel or vehicle wiring harness. This termin